Ideal Uses: Home, Office, Building, Warehouse, Farms, Wood, Working area etc.
| MODEL NO. | RSP-01 | RSP-02 | RSP-04 | RSP-06 | RSP-09 |
|---|---|---|---|---|---|
| CAPACITY IN KG | 1 KG | 2 KG | 4 KG | 6 KG | 9 KG |
| I.S. SPECIFICATION NO. | IS 15683 | IS 15683 | IS 15683 | IS 15683 | IS 15683 |
| FIRE RATING | 1A, 21B | 1A, 21B | 2A, 55B | 3A, 89B | 4A, 144B |
| OVERALL HEIGHT (MM) | 320 MM | 375 MM | 460 MM | 480 MM | 585 MM |
| COMPLETE WEIGHT (APPR. KG) | 2 kg | 3.3 kg | 6.2 kg | 8.6 kg | 12.5 kg |
| EMPTY WEIGHT (APPR. KG) | 0.1 kg | 1.3 kg | 2.2 kg | 2.6 kg | 3.5 kg |
| OPERATING TEMP. °C | -20°C to +60°C | -20°C to +60°C | -20°C to +60°C | -20°C to +60°C | -20°C to +60°C |
| DIA. OF CYLINDER (MM) | 86±10 mm | 108±10 mm | 140±10 mm | 160±10 mm | 175±10 mm |
| RANGE OF DISCHARGE (M) | 2 m | 2 m | 2 m | 2 m | 2 m |
| DURATION OF DISCHARGE (SEC) | 8 sec | 8 sec | 13 sec | 13 sec | 15 sec |
| TEST PRESSURE (MIN) | 35 kgf/cm² | 35 kgf/cm² | 35 kgf/cm² | 35 kgf/cm² | 35 kgf/cm² |
| WORKING PRESSURE | 15 kgf/cm² | 15 kgf/cm² | 15 kgf/cm² | 15 kgf/cm² | 15 kgf/cm² |
| BURST PRESSURE (MIN) | 55 kgf/cm² | 55 kgf/cm² | 55 kgf/cm² | 55 kgf/cm² | 55 kgf/cm² |
| APPROVALS | BIS | BIS | BIS | BIS | BIS |
Ideal Uses: Home, Office, Building, Warehouse, Farms, Wood, Working area etc.
| MODEL NO. | RBC-04 | RBC-06 | RBC-09 |
|---|---|---|---|
| CAPACITY IN KG. | 04 KG | 06 KG | 09 KG |
| I.S. SPECIFICATION NO. | IS 15683 | IS 15683 | IS 15683 |
| FIRE RATING | 55 B | 89 B | 144 B |
| CO2 GAS CARTRIDGE (GMS) | 90 gm | 120 gm | 200 gm |
| COMPLETE WEIGHT (APPR.KG) | 7.9 kg | 10.2 kg | 14.4 kg |
| EMPTY WEIGHT (APPR. KG) | 3.9 kg | 4.2 kg | 5.4 kg |
| OVERALL HEIGHT (M/M) | 480 mm | 505 mm | 575 mm |
| OPERATING TEMP °C | -20°C to +60°C | -20°C to +60°C | -20°C to +60°C |
| DIA. OF CYLINDER (M/M) | 140 ±10 | 160 ±10 | 175 ±10 |
| RANGE OF DISCHARGE (M) | 2 m | 2 m | 2 m |
| DURATION OF DISCHARGE (SEC) | 9 Sec | 9 Sec | 15 Sec |
| TEST PRESSURE (MIN) | 35 kgf/cm² | 35 kgf/cm² | 35 kgf/cm² |
| WORKING PRESSURE | 15 kgf/cm² | 15 kgf/cm² | 15 kgf/cm² |
| BURST PRESSURE (MIN) | 55 kgf/cm² | 55 kgf/cm² | 55 kgf/cm² |
| APPROVALS | BIS | BIS | BIS |
Ideal Uses: Chemical Manufacturing Plant, Oil Rings, Rail Yard, Warehouse, Construction Site, Parking, Garages, Airports, Electrical, Substation, and Large Laboratories.
| MODEL NO. | RCO2-02 | RCO2-03 | RCO2-4.5 |
|---|---|---|---|
| CAPACITY IN KG. | 2 KG | 3 KG | 4.5 KG |
| I.S. SPECIFICATION NO. | IS 15683 | IS 15683 | IS 15683 |
| FIRE RATING | 21 B | 34 B | 55 B |
| OVERALL HEIGHT (M/M) | 540 mm | 540 mm | 685 mm |
| COMPLETE WEIGHT (APPR.KG) | 7.9 kg | 12.8 kg | 15.5 kg |
| EMPTY WEIGHT (APPR. KG) | 5.9 kg | 9.8 kg | 11 kg |
| OPERATING TEMP. °C | -20°C to +60°C | -20°C to +60°C | -20°C to +60°C |
| DIA. OF CYLINDER (M/M) | 108 mm | 140 mm | 140 mm |
| RANGE OF DISCHARGE (M) | 2 m | 2 m | 2 m |
| DURATION OF DISCHARGE (SEC) | 8 Sec | 8 Sec | 8 Sec |
| TEST PRESSURE (MIN) | 250 kgf/cm² | 250 kgf/cm² | 250 kgf/cm² |
| WORKING PRESSURE | 150 kgf/cm² | 150 kgf/cm² | 150 kgf/cm² |
| CLASS OF FIRE | B, C | B, C | B, C |
| EXTINGUISHER MEDIA | CO2 Gas IS:15222 | CO2 Gas IS:15222 | CO2 Gas IS:15222 |
| APPROVALS | BIS | BIS | BIS |
Ideal Uses: Chemical Manufacturing Plant, Oil Rings, Rail Yard, Warehouse, Construction Site, Parking, Garages, Airports, Electrical, Substation, and Large Laboratories.
| CAPACITY IN KG | 6.5 KG | 9 KG | 22.5 KG |
|---|---|---|---|
| I.S. SPECIFICATION NO. | IS 16018 | IS 16018 | IS 16018 |
| FIRE RATING | 55 B | 55 B | 89 B |
| OVERALL HEIGHT (MM) | 970 mm | 1210 mm | 1035 mm |
| COMPLETE WEIGHT (APPR.KG) | 25.5 kg | 32.5 kg | 67 kg |
| EMPTY WEIGHT (APPR. KG) | 19 kg | 23.5 kg | 44.5 kg |
| OPERATING TEMP. °C | -30°C to +55°C | -30°C to +55°C | -30°C to +55°C |
| DIA. OF CYLINDER (M/M) | 140 mm | 140 mm | 232 mm |
| RANGE OF DISCHARGE (M) | 3.5 m | 4 m | 4 m |
| DURATION OF DISCHARGE (SEC - MIN) | 15–20 Sec | 30–35 Sec | 30–60 Sec |
| TEST PRESSURE (MIN) | 250 kgf/cm² | 250 kgf/cm² | 250 kgf/cm² |
| WORKING PRESSURE | 150 kgf/cm² | 150 kgf/cm² | 150 kgf/cm² |
| CYLINDER | SEAMLESS IS 7285 | SEAMLESS IS 7285 | SEAMLESS IS 7285 |
| MIN. DISCHARGE % | 95% | 95% | 95% |
| CLASS OF FIRE | B, C | B, C | B, C |
| APPROVALS | BIS | BIS | BIS |
Ideal Uses: Petrol Station, Restaurant, etc. (Foam Extinguishers are not suitable for fire involving electrical rish dont use on Electrical Fire)
| MODEL NO. | RCM-9 | RSPM-9 | RCM-45 | RSPM-150 |
|---|---|---|---|---|
| CAPACITY IN KG. | 9 LTR | 9 LTR | 45 LTR | 150 LTR |
| I.S. SPECIFICATION NO. | IS 15683 | IS 15683 | IS 16018 | As Per IS |
| FIRE RATING | 4A, 144B | 4A, 144B | 20A, 233B | - |
| COMPLETE WEIGHT (APPR.KG) | 14 kg | 12.6 kg | 76 kg | 245 kg |
| EMPTY WEIGHT (APPR.KG) | 5 kg | 3.6 kg | 31 kg | 95 kg |
| OVERALL HEIGHT (M/M) | 570 mm | 585 mm | 1010 ± 20 mm | 1110 ± 20 mm |
| OPERATING TEMP °C | +5°C to +60°C | +5°C to +60°C | +5°C to +55°C | +5°C to +55°C |
| DIA. OF CYLINDER (M/M) | 175 ±10 mm | 175 ±10 mm | 300 ±10 mm | 600 ±20 mm |
| RANGE OF DISCHARGE (M) | 2 m | 2 m | 6 m | 12 m |
| DURATION OF DISCHARGE (SEC) | 15 Sec | 15 Sec | 60–180 Sec | 180–300 Sec |
| CHARGE PRESSURE | 15 kgf/cm² | 15 kgf/cm² | 5 kgf/cm² | 5 kgf/cm² |
| TEST PRESSURE | 35 kgf/cm² | 35 kgf/cm² | 35 kgf/cm² | 35 kgf/cm² |
| APPROVALS | BIS | BIS | BIS | BIS |
Ideal Uses: School, Theaters, Apartments and Office, Dry goods store. (Water extinguisher is not suitable for fires involving electrical risk. Don't use on Electrical Fire.) Oil Refineries, turbines & chemical industries, boiler rooms, garage forecourt Factories, restaurants, paint shops, tubes & flaps units, petrol bunks, chemical & petroleum bulk storage depots.
| MODEL NO. | RCW-9 | RSPM-9 | 45 LTR | 150 LTR |
|---|---|---|---|---|
| CAPACITY IN KG. | 9 LTR | 9 LTR | 45 LTR | 150 LTR |
| FIRE RATING | IS 15683 | IS 15683 | IS 16018 | A as Per IS |
| FIRE RATING | 3A | 3A | 20A | - |
| COMPLETE WEIGHT (APPR. KG) | 13.6 kg | 3.5 kg | 76 kg | 245 kg |
| EMPTY WEIGHT (APPR. KG) | 4.6 kg | 12.5 kg | 31 kg | 95 kg |
| OVERALL HEIGHT (MM) | 570 mm | 585 mm | 1010 mm | 1110 ± 20 mm |
| OPERATING TEMP. | +5°C to +60°C | +5°C to +60°C | +5°C to +55°C | +5°C to +55°C |
| DIA. OF CYLINDER (MM) | 175 ± 10 mm | 175 ± 10 mm | 300 ± 20 mm | 600 ± 20 mm |
| RANGE OF DISCHARGE (M) | 2 m | 2 m | 6 m | 12 m |
| DURATION OF DISCHARGE (SEC) | 13 sec | 15 sec | 60–180 sec | 180–300 sec |
| BURST PRESSURE (MIN) | 55 kgf/cm² | 55 kgf/cm² | 55 kgf/cm² | 55 kgf/cm² |
| TEST PRESSURE (MIN) | 35 kgf/cm² | 35 kgf/cm² | 35 kgf/cm² | 35 kgf/cm² |
| WORKING PRESSURE | 15 kgf/cm² | 15 kgf/cm² | CO₂ Gas IS:15222 | CO₂ Gas IS:15222 |
| APPROVALS | BIS | BIS | BIS | BIS |
Ideal Uses:Computer, Telephone,Switchgears, Sensitive data storage,offices, Boats, Aircraft's, Laboratories ect.
| MODEL NO. | RCW-9 | RSPM-9 | 45 LTR | 150 LTR |
|---|---|---|---|---|
| CAPACITY IN KG. | 9 LTR | 9 LTR | 45 LTR | 150 LTR |
| FIRE RATING | IS 15683 | IS 15683 | IS 16018 | A as Per IS |
| FIRE RATING | 3A | 3A | 20A | - |
| COMPLETE WEIGHT (APPR. KG) | 13.6 kg | 3.5 kg | 76 kg | 245 kg |
| EMPTY WEIGHT (APPR. KG) | 4.6 kg | 12.5 kg | 31 kg | 95 kg |
| OVERALL HEIGHT (MM) | 570 mm | 585 mm | 1010 mm | 1110 ± 20 mm |
| OPERATING TEMP. | +5°C to +60°C | +5°C to +60°C | +5°C to +55°C | +5°C to +55°C |
| DIA. OF CYLINDER (MM) | 175 ± 10 mm | 175 ± 10 mm | 300 ± 20 mm | 600 ± 20 mm |
| RANGE OF DISCHARGE (M) | 2 m | 2 m | 6 m | 12 m |
| DURATION OF DISCHARGE (SEC) | 13 sec | 15 sec | 60–180 sec | 180–300 sec |
| BURST PRESSURE (MIN) | 55 kgf/cm² | 55 kgf/cm² | 55 kgf/cm² | 55 kgf/cm² |
| TEST PRESSURE (MIN) | 35 kgf/cm² | 35 kgf/cm² | 35 kgf/cm² | 35 kgf/cm² |
| WORKING PRESSURE | 15 kgf/cm² | 15 kgf/cm² | CO₂ Gas IS:15222 | CO₂ Gas IS:15222 |
| APPROVALS | BIS | BIS | BIS | BIS |
Class K Fires are fires that involve cooking oils, grease or animal for and can be extinguished using Wet Chemical, the typical agent found in kitchen fire extinguisher.
Suitable For- Kitchen Fire.(Vegitable/Animal Oil & Fat)
Fire Ideal Usage- Kitchen Fire
| Available Capacity | 4kg, 6kg, & 9kg |
| Working Temperature | +5°C to +55°C |
| Cylinder Testing Pressure | 30 Bar |
| Service Pressure | 15 Bar |
| Filling Tolerance | 0,(−)5% by Volume |
| Minimum Effective Discharge Time | 8 Seconds |
| Discharge Quality | More than 90% |
The only type of Class D fire extinguisher is the Dry Powder extinguisher. The powder agent used may be either powdered graphite, granular sodium chloride or copper based, all of which are effective at separating the fuel (the ignited combustible metal) from the oxygen
| DESCRIPTION | 4 KG | 6 KG | 9 KG |
|---|---|---|---|
| BIS Specification | As Per 15683 | As Per 15683 | As Per 15683 |
| Extinguishing Media | TEC Powder | TEC Powder | TEC Powder |
| Discharge Time Sec. | More Than 13 | More Than 13 | More Than 13 |
| Test Pres. Kgf/Cm² | 35 | 35 | 35 |
| Operating Temp. Range | +10°C to +60°C | +10°C to +60°C | +10°C to +60°C |
| Rating | 21B | 34B | 55B |
Ideal Uses: Home, Office, Building, Warehouse, Farms, Wood, Working Area etc.
| CAPACITY IN KG | 25KG (INSIDE) | 25KG | 50 KG | 75 KG |
|---|---|---|---|---|
| I.S. SPECIFICATION NO. | IS 16018 | IS 16018 | IS 16018 | IS 16018 |
| CO2 GAS CARTRIDGE (GMS) / CYLINDER | 500 gm | 1 kg | 2 kg | 2 kg |
| EMPTY WEIGHT (APPR. KG) | 24.5 kg | 31 kg | 51 kg | 71.5 kg |
| COMPLETE WEIGHT (APPR. KG) | 49.5 kg | 56 kg | 101 kg | 146.5 kg |
| OVERALL HEIGHT (MM) | 750 | 800 | 1040 | 1180 |
| TEST PRESSURE (MIN) | 30 kgf/cm² | 30 kgf/cm² | 30 kgf/cm² | 30 kgf/cm² |
| MIN. DISCHARGE | 85% | 85% | 85% | 85% |
| DIA OF CYLINDER (MM) | 300 mm | 300 mm | 450 mm | 400 mm |
| RANGE OF DISCHARGE (M) | 6 m | 6 m | 6 m | 6 m |
| DURATION OF DISCHARGE (SEC) | 25 sec | 25 sec | 40 sec | 50 sec |
| FIRE RATING | 233B | 233B | 233B | 233B |
| OPERATING TEMP. °C | -30°C to +55°C | -30°C to +55°C | -30°C to +55°C | -30°C to +55°C |
| APPROVALS | BIS | BIS | BIS | BIS |
Ideal Uses: Protection of computer area, ATM Center, server room, Fuel and flammable liquid storage, oil fill-in stations, transformers, automobile garages, marine engines, paint and varnish booths, welding benches, domestic gas Storage's particularly for hotels etc.
| MODEL NO. | RMP-2 | RMP-5 | RMP-10 | RMP-15 |
|---|---|---|---|---|
| CAPACITY IN KG | 02 KG | 05 KG | 10 KG | 15 KG |
| PROPELLANT | NITROGEN | NITROGEN | NITROGEN | NITROGEN |
| WORKING PRESSURE | 7 TO 15 kg/cm² | 7 TO 15 kg/cm² | 7 TO 15 kg/cm² | 7 TO 15 kg/cm² |
| TESTING PRESSURE | 35 kg/cm² | 35 kg/cm² | 35 kg/cm² | 35 kg/cm² |
| AREA PROTECTION | 1 to 1.5 m² | 3.5 to 4 m² | 5 to 6 m² | 6 to 7 m² |
| VOLUME PROTECTION | 3 m³ | 3 m³ | 15 m³ | 20 m³ |
| HANDING VERTICALLY ABOVE RISK | 1.5 m | 1.5 to 2 m | 1.7 to 2.25 m | 2 to 3 m |
| OPERATION TIME IN SECONDS | 8–9 Sec | 10–15 Sec | 15–20 Sec | 18–23 Sec |
| EXTINGUISHER MEDIA | MONOAMMONIUM PHOSPHATE (MAP) | |||
Ideal Uses: Protection of computer area, ATM Center, server room, Fuel and flammable liquid storage, oil fill-in stations, transformers, automobile garages, marine engines, paint and varnish booths, welding benches, domestic gas Storage's particularly for hotels etc.
| MODEL NO. | RMC-2 | RMC-5 | RMC-10 | RMC-15 |
|---|---|---|---|---|
| CAPACITY IN KG | 02 KG | 05 KG | 10 KG | 15 KG |
| CLASS OF FIRE | ABC | ABC | ABC | ABC |
| WORKING PRESSURE | 7 TO 15 kg/cm² | 7 TO 15 kg/cm² | 7 TO 15 kg/cm² | 7 TO 15 kg/cm² |
| TESTING PRESSURE | 35 kgf/cm² | 35 kgf/cm² | 35 kgf/cm² | 35 kgf/cm² |
| AREA PROTECTION | 1 to 1.5 m² | 3 to 4 m² | 5 to 6 m² | 6 to 7 m² |
| VOLUME PROTECTION | 3m | 3m | 15m | 20m |
| HANGING VERTICALLY ABOVE RISK | 1.5 m | 1.5 to 2 m | 1.7 to 2.25 m | 2 to 3 m |
| OPERATION TIME IN SECONDS | 08-10 Sec | 10-15 sec | 15-20 sec | 18-23 Sec |
| EXTINGUISHER MEDIA | HFC 227ea | |||
Ideal Uses: Fire trace fire suppression systems keep your business, people and equipment safe by automatically detecting and suppressing fires in high-risk equipment, like CNC machines, vehicles, heavy equipment, ectrical cabinets, and wind turbines.
| MODEL NO | MF-2CA | MF-4 CA | MF-6 CA | MF-9CA |
|---|---|---|---|---|
| EXTINGUISHER BODY | MS | MS | MS | MS |
| CAPACITY (KG) | 2KG | 4KG | 6KG | 9KG |
| EXTINGUISHING MEDIUM | CLEAN AGENT | CLEAN AGENT | CLEAN AGENT | CLEAN AGENT |
| FIRE TRACE TUBE END FITTING | PRESSURE GAUGE | PRESSURE GAUGE | PRESSURE GAUGE | PRESSURE GAUGE |
| FIRE TRACE TUBE | RAPTURE ON TOUCH OF ACTUAL FIRE | RAPTURE ON TOUCH OF ACTUAL FIRE | RAPTURE ON TOUCH OF ACTUAL FIRE | RAPTURE ON TOUCH OF ACTUAL FIRE |
| OPERATING PRESSURE | 15 BAR | 15 BAR | 15 BAR | 15 BAR |
| TEST PRESSURE | 35 BAR | 35 BAR | 35 BAR | 35 BAR |
| EXPELLANT | NITROGEN | NITROGEN | NITROGEN | NITROGEN |
Fire extinguisher ball is new and advanced technology from German, harmless to the Humanity and the environment. It is self activating and safe explosive range. It is easy to use and install. It does not require any training to use this extinguisher .It is also known as AUTO FIRE OFF an dis made from ultra high quality powder. It is A B C Dry Powder Type Extinguisher. It does not require refilling and it is very effective to take control over the fire in 3 to 5 seconds. It is also approved by SGS.
Lithium-ion battery fires are Class B fires, indicating the presence of flammable liquids, so a standard dry chemical or ABC extinguisher can put them out. Lithium battery fire extinguishers counteract the liquid electrolytes in the battery that create conductive pathways.
Breathing apparatus Is provided to help you safely evacuate a confined space if the gas monitoring equipment indicates a problem with the atmosphere. It will also help sustain ilfe if you get into difficulties whilst in a confined space, until you can be rescued by the emergency services.
It is used in places like a boiler room, pump room, engine room, etc. They can be used in any sizeable but closed space under fire for extinguishing the fire quickly and robustly. There is a high probability that a fire will occur in various ship rooms.
Clean agent systems are extinguishment systems, they're chemical extinguishment systems that extinguish a fire without using any water.They're gaseous total flooding systems, flooding a protected room or compartment with gas, floor to ceiling, wall to wall, no matter where the fire is until it goes out.
Commercial kitchen fire suppression systems are designed to keep a fire that has started on a kitchen appliance such as a stove or deep fat fryer from raging out of control. According to the National Fire Protection Association (NFPA), 61% of fires in eating and drinking establishments are caused by cooking equipment.